Door Interlock Switch - GE Profile PDW8200 Series Technical Service Manual

Hide thumbs Also See for Profile PDW8200 Series:
Table of Contents

Advertisement

4. With the panel hanging over the escutcheon,
rotate the bottom of the stainless steel outer
panel back so it is flush with the door assem-
bly. Make sure that the sides of the outer panel
fit around the hinge arms.
5. Look at the fit between the escutcheon and the
stainless steel outer panel front opening. Make
sure that the protruding ribs from the escutch-
eon fit inside the stainless steel front opening.
Adjust the position of the outer panel up or
down, left or right to center the panel with the
escutcheon.
6. Once the panel is centered, install the 2
screws in the bottom of the panel to connect
the stainless steel outer panel to the hinge
arms. Recheck to make sure the escutcheon
ribs are protruding through the panel opening.
7.
While holding the outer panel against the door
assembly, slowly open the door to about 45
degrees open so that the remaining 8 panel
screws can be installed (4 screws on each
side).

Door Interlock Switch

The door interlock switch opens the L1 circuit and
Neutral circuit when the door is open.
Caution: After removing the screws from the
escutcheon keypad assembly, the assembly is
still attached to the control module by 2 ribbon
cables. Dropping or rough handling of the escutch-
eon will cause the ribbon cable to tear, and the
entire escutcheon keypad assembly will need to
be replaced.
1. Remove the escutcheon keypad assembly
(see Escutcheon Keypad Assembly).
2. Remove 2 screws and the switch from the
door.
3. Carefully remove the cover from the switch
and unplug the blade connectors.
Note: The wire color code is on the switch cover.
2 Screws
DOOR INTERLOCK SWITCH
DOOR
DOOR
BW
BX
WX
WR
J2-7
COM
NO
NO COM
BW
J2-8
J1-1
BX
J1-3
N
L1
Page 16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents