2. PRINTER SETUP

2.9.6 Real Time Clock Setting

NOTE:
The Real Time Clock Setting is
effective only when an optional Real
Time Clock, B-SA704-RTC-QM-R, is
installed.
NOTE:
Use the [FEED] or [RESTART] key
to set the value.
While "<8>RTC SET" is displayed on the LCD Message Display, press
the [PAUSE] key to enter the Real Time Clock Setting Mode.
The Real Time Clock Setting Mode contains the following sub menus.
Each time the [PAUSE] key is pressed, the sub menus are displayed
sequentially.
(1) Date setting (Year, Month, Day)
(2) Time setting (Hour, Minute, Second)
(3) Low battery check setting
(4) RTC data renewal timing setting
(1) Date Setting
This parameter is to set the Year, Month, and Day, in order.
When "<8>RTC SET" appears, press the [PAUSE] key.
DATE
05/01/01
Press the
[PAUSE]
key to set the date.
DATE Y 06/01/01
[PAUSE]
DATE M 06/03/01
[PAUSE]
DATE D 06/03/01
After selecting the date, press the [PAUSE] key.
(2) Time Setting
This parameter is to set the Hour, Minute, and Second, in order.
TIME
00/00/00
Press the [PAUSE] key to set the time.
TIME H 10/01/01
[PAUSE]
TIME M 10/30/01
[PAUSE]
TIME S 10/30/00
After selecting the time, press the [PAUSE] key.
E2-32
ENGLISH VERSION EO1-33055
2.9 Setting an Operating Environment
Year
Month
Day
Hour
Minute
Second