Sony BKS-R3219 Operation Manual page 16

Universal control unit
Hide thumbs Also See for BKS-R3219:
Table of Contents

Advertisement

Preparations
Setting to 32-source (BKS-R3219) or 16-
source (BKS-R1618) select mode
While holding down buttons 1 and 4, turn the power
on.
All the source/destination select buttons work as
source select buttons.
Setting to 16-source/16-destination select
mode 1 (BKS-R3219) or 8-source/8-destination
select mode (BKS-R1618)
While holding down buttons 5 and 6, turn the power
on.
Select buttons 1 through 8 and 17 through 24 of the
BKS-R3219 or buttons 1 to 8 of the BKS-R1618
function as source select buttons, and select buttons 9
through 16 and 25 through 32 of the BKS-R3219 or
buttons 9 to 16 of the BKS-R1618 function as
destination select buttons.
Setting to 16-source/16-destination select
mode 2 (BKS-R3219) or 16-source select
mode (BKS-R1618)
While holding down buttons 5 and 7, turn the power
on.
Upper select buttons 1 through 16 function of the
BKS-R3219 as source select buttons, and lower select
buttons 17 through 32 of the BKS-R3219 function as
destination select buttons.
All select buttons of the BKS-R1621 function as
source select buttons.
Setting to phantom full-protect mode
While holding down buttons 9 and 11, turn the power
on.
If one of the crosspoints set for a phantom is protected,
switching of all the crosspoints of the phantom is
prohibited.
Setting to phantom partial-protect mode
While holding down buttons 9, 10 and 11, turn the
power on.
If one of the destinations set on a phantom is protected,
switching of the crosspoints, including the protected
destination, is prohibited, but the other crosspoints are
switched.
Entering station number setting mode
While holding down buttons 1, 2, 3 and 4, turn the
power on.
The station number can be set with binariy coding
using buttons 1 through 8.
16
Resetting the software
Press and hold the LOCK and PROT buttons for five
seconds.
Then the software is reset, and the same status as the
power is turned on is obtained.
List of setup operations
Settings
Initialization
Single-use mode
Prompt lamp-light mode
Status display lamp-light mode
32-source (BKS-R3219) or 16-source
(BKS-R1618)select mode
16 source/16 destination select mode 1
(BKS-R3219) or 8-source/8-destination
select mode (BKS-R1618)
16 source/16 destination select mode 2
(BKS-R3219) or 16-source select mode
(BKS-R1618)
Phantom full-protect mode
Phantom partial-protect mode
Station number setting mode
Buttons to be
pressed
1, 2
5, 8
1, 3
1, 2, 3
1, 4
5, 6
5, 7
9, 11
9, 10, 11
1, 2, 3, 4