8.6 Alarm Setup
The dome camera supports 7 alarm inputs and 2 outputs; It can realize
alarm-linkage, external alarm info transmitting to camera, alarm position
shooting (evoke presets, or startup auto touring, auto learning and scan), and
decides executing the alarm output or not.
1. Press 'MENU' on the keyboard or evoke the presets no. 95 and 64 to enter
the main menu, or press the preset no.1 twice continuously within 1 second.
REPOSTION 2 options: 'ON'-Delete alarm output, and the camera will
stop. 'OFF' –delete alarm output and the camera will keep the current
status. The delay time must be longer than 3 seconds while setting this
function to be 'ON'
DELAY TIME Set the time that system will auto reset the alarm after
current alarm inputs. Values: 1 to 255 seconds
OUTPUT STATUS
(Normal Open or Normal Close). Choosing NC, the relay will be closed
when there is no alarm output; and the replay will be opened while there is
any alarm output.
8.6.1 Active Settings
Move the cursor to Active Settings, select the item to access its submenu.
[NO. ] Edit the number of alarm input channel(001-007).When there are
two alarm inputs number 001 and number 002 at the same time, the
dome will respond to number 001 first.
[ALARM LINKAGE] Set auto respond function. OFF/ Auto Panning/
Pattern / Preset Cruise /Call preset. For example: Alarm channel 001 call
preset 1, alarm channel 002 call preset 2.
[ALARM ACTION] Select respond output channel for current alarm input.
OFF, 1, 2, 1&2
[ALARM OUTPUT]: Alarm outputs options while there is alarm input:
Null-no Alarm output/alarm output 1/alarm output 2/both.
8.6.2 Placement Set
Move joystick and make the cursor to [Placement set], and enter the
placement set menu, there are 2 modes:
[ON] Enable this function
[OFF] Disable this function
[START/END TIME] Set the start/end time period for alarm; If the placement
state is On, START/END TIME must be set to make the
alarm action effective.
A larm lin e
Vi d eo li ne
7
6
5
4
3
2
A LA RMS
B N C
High Speed Dome Camera User's Manual
Set relay status. There are 2 states. NO or NC
Co ntro l lin e/
Po wer line r
1
B -
A+
G N D
O U T1
O U T 2
R s485
Pin alarm connection paraphrase:
7 Pin alarm input
BLUE
PINK
WHITE
BLACK
RED
ORANGE
YELLOW
GREEN
2Pin alarm output
AQUA
AZURY
PURPLE
AC 24V
BROWN
GRAY
SHIELD
- 22 -
ALMIN COM
ALARM-1IN
ALARM-2IN
ALARM-3IN
ALARM-4IN
ALARM-5IN
ALARM-6IN
ALARM-7IN
ALMOUT- COM
ALMOUT-1 NC
ALMOUT-1NO
ALMOUT-2COM
ALMOUT-2NC
ALMOUT-2 NO