Scan Setup - Hitachi VK-S454ER User Manual

High speed dome camera
Hide thumbs Also See for VK-S454ER:
Table of Contents

Advertisement

MAIN MENU
1. DISPLAY SETTINGS
2. CAMERA SETTINGS
3. PRIVACY MASK
4. USER PROGRAM
5. SYSTEM SETTINGS
6. LANGUAGE/
7. EXIT
USER PROGRAM
1. PRESET SETUP
2. TOUR SETUP
3. AUTO LEARNING

4. SCAN SETUP

5. TIMER SETUP
6. ALARM SETUP
7. RETURN
SCAN SETUP
1. NO.
001
2. PATH
>=180
3. SPEED
050
4. START POSITION
5. END POSITION
6. EXECUTE
7. DELETE
8. RETURN
8.4 Scan Setup
1. Preset 2 points first, the camera will scan between 2 presets horizontally with stable speed
and same zoom time. A speed dome camera has 4 groups of scans.
2. Press 'MENU' on the keyboard or evoke the presets no. 95 and 64 to enter the main menu;
choose menu to enter the 'SCAN SETUP' as shown in the left figures.
3. Choose [NUMBER], There are 4 scans available.
4. Scan Speed Setup: move the cursor to [SPEED] to choose from 001-063;
5. Start Position Move the cursor to [START POSTITION]; move the joystick to choose object
image, press [OPEN] to save. The end position setup is the same way as start position.
6. Execute the scan: Make the cursor to [EXECUTE], and move the joystick to enter the menu.
The camera will execute the scans.
7. [DELETE]: Delete current scan.
Note:
1. If the start position and end position are the same point, the camera will run at
constant speed.
2. During the scan, the speed, zoom time and vertical direction will keep unchanged; if
these parameters are not the same for the 2 points, the scanning will be subject to
the start position.
3. Auto scanning will be titled automatically, which will be displayed on the screen, like
auto scan 001.
High Speed Dome Camera User's Manual