andrews CSC39 Installation Manual, Operation And Service Manual page 17

Natural gas, propane & butane fired storage water heaters
Table of Contents

Advertisement

SECTION 3
FLUE
SYSTEMS
Fig 4.
Fig 5.
14
INSTALLATION
INSTALLING THE FLUE TERMINAL
NOTE! The horizontal flue terminal supplied may be used through outside walls up to
600mm (24in) thick.
1. Horizontal flue Terminal (Through the Wall) supplied
a) Cut an opening of at least 165mm (6.5in) diameter through the outside for the
58.7kWh input models or 216mm (8.5in) for the 88kWh and 105.6kWh input models.
b) Slide the flue terminal through the wall opening to the rib closest to the intake air
openings of the terminal even with the outside wall.
flue Terminal
Outer Wall
Mount Plate
c) Slide the outside wall plate over the flue terminal and fasten to the wall with four
screws. Depending on the wall construction, wall anchors may be required to reinforce
the screws.
d) Install inside wall plate on the inside wall and secure with four screws. Depending on
wall construction, wall anchors may be required to reinforce the screws.
Inner Wall
Mount Plate
Screw
(Supplied)
(4 Places)
Intake Air Openings
(Must Face Ground)
Hole through Wall
Screw
(Supplied)
(4 Places)
Hole through Wall
Wall Anchor
(4 Places)
Flue Terminal
Wall Anchor
(4 Places)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csc59Csc78Csc93Cscl39Cscl59Cscl78 ... Show all

Table of Contents