Serial Port Specifications; Cabling Pinouts If Pin 7 Is Used - HP AA-RSB6B-TE Installation Manual

Storageworks san switch 2/8 el and san switch 2/8 power pak models
Table of Contents

Advertisement

Technical Specifications

Serial Port Specifications

The Serial port can be used to connect to a computer workstation to configure the
switch IP address without connecting to the fabric. The Serial port's parameters
are 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control.
The port requires a straight serial cable with a female 9-pin subminiature-D
connector. Only pins 2, 3, and 5 are supported; if pin 7 is used, the signal must
always be driven high, using the pinouts listed in
Table 9: Cabling Pinouts if Pin 7 is Used
1
2
3
4
5
6
7
8
9
Note:
serial port and should be kept on the port whenever the serial port is not in use.
88
PIN
Signal
TxData
RxData
GND
CTS
For dust and ESD (electrostatic discharge) protection, a cover is provided for the
Table
Description
Transmit Data
Receive Data
Logic Ground
Clear to Send
hp StorageWorks SAN Switch 2/8 Installation Guide
9.

Advertisement

Table of Contents
loading

Table of Contents