Mitsubishi Electric MXZ-2C30VA Service Manual page 114

Split-type air conditioners outdoor unit
Hide thumbs Also See for MXZ-2C30VA:
Table of Contents

Advertisement

OPERATING PROCEDURE
4. Removing the expansion valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel (Photo 1).
(Gas recovery is not required if the unit is pumped down.)
(3) Remove the front panel for removing LEV G (Photo 1).
(4) Remove the electrical parts for removing LEV G (Photo 3, 4).
(5) Remove the LEV coils.
(6) Detach the brazed parts of expansion valves and pipes.
Photo 7
Suction pipe
brazed part
Discharge pipe
brazed part
Compressor nuts
Photo 8
114
PHOTOS
LEV coils
2 way valve solenoid coil
HPS
LEV coils G
Expansion
valves
Expansion
valves

Hide quick links: