System Board - HP ProLiant ML310 Generation 4 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML310 Generation 4:
Table of Contents

Advertisement

WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
Power down the server (on page 25).
1.
Remove the server from the rack, if necessary
2.
Remove the bezel
3.
Remove the access panel
4.
Locate the battery
5.
Remove the battery.
6.
To replace the component, reverse the removal procedure.
IMPORTANT:
settings. The user can update these settings using RBSU.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.

System board

To remove the component:
Power down the server (on page 25).
1.
Remove the server from the rack, if necessary
2.
Remove the bezel
3.
The computer contains an internal lithium manganese dioxide, a vanadium
("Unlock the tower
bezel" on page 26).
("Access
panel" on page 26).
("System board
components" on page 62).
After replacing the battery, the server is automatically configured with the default
("Unlock the tower
bezel" on page 26).
("Remove the server from the
("Remove the server from the
Removal and replacement procedures 46
rack" on page 25).
rack" on page 25).