Error/Warning Indications
The camcorder informs you of situations where warning, caution, or an operation check is required,
through messages on the LCD/viewfinder screen, the recording lamp, and a buzzer.
The buzzer is output to the headphones connected via the headphone connector.
Error indications
The camcorder stops operation after the following indications.
Error indication on
Buzzer
LCD/viewfinder
C:04:ss
C:06:ss
C:32:ss
E:20:ss/E:40:ss/
E:41:ss/E:50:ss/
E:51:ss/E:61:ss/
E:62:ss/E:92:ss/
E:94:ss/E:95:ss
Warning indications
When one of the following indications is generated, follow the message to resolve the problem.
Warning indication
Buzzer
on LCD/viewfinder
Media Near Full
Intermittent
Media Full
Continuous
Battery Near End
Intermittent
Battery End
Continuous
Battery Temperature
High
Turn Power Off
Temperature High
Intermittent
Battery Error
Please Change Battery
Recording
Cause and measures
lamp
The battery pack is not an "InfoLITHIUM" battery pack. Use
an "InfoLITHIUM" battery pack (page 54).
The battery pack temperature is high. Change the battery
pack or place it in a cool place.
Remove the power source. Reconnect it and operate your
camcorder again.
Perform the following steps.
1 Check the list, and inspect your camcorder.
2 Disconnect the power source, attach the power source again
after about 1 minute, and turn the camcorder on.
3 Contact your Sony dealer or local authorized Sony service
facility.
Recording
Cause and measures
lamp
Flashing
Free space on the XQD memory card has become
insufficient.
Replace it with another at the earliest opportunity.
Rapidly
No space is left on the XQD memory card. Recording, clip
flashing
copying and clip division cannot be performed.
Replace it with another.
Flashing
The battery power will be discharged soon.
Charge the battery pack at the earliest opportunity.
Rapidly
The battery pack is discharged. Recording cannot be
flashing
performed.
Stop operation and change the battery pack.
The temperature of the battery pack has risen above a safe
operation limit.
The camcorder turns off automatically.
Flashing
The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.
An error was detected with the battery pack.
Replace the battery pack with a normal one.
Error/Warning Indications