Download Print this page

Honeywell T410A Installation Instructions page 2

Line voltage electric heat thermostats
Hide thumbs Also See for T410A:

Advertisement

T410A,B LINE VOLTAGE ELECTRIC HEAT THERMOSTATS
3
WIRE AND MOUNT NEW THERMOSTAT
Remove thermostat cover by grasping the top and
bottom ends with fingers, and pulling outward.
Connect wires to the thermostat as shown in the
applicable wiring diagram. Push the wires into the
outlet box, and insert the thermostat into the box for
mounting by pushing against top and bottom of the
thermostat base.
Do not press on setting knob.
IMPORTANT:
Secure the thermostat to the box with the two captive
mounting screws provided.
Replace thermostat cover.
Set knob to desired room temperature.
Rough handling or strong pressure can
IMPORTANT:
damage knob or sensing element, and change
calibration.
1
T410B
L2
L1
3
2
4
T2
T1
3
TO
ELECTRIC
HEATER
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
2
BREAKS ON POSITIVE OFF.
3
EXPOSED UNUSED LEADWIRES TO BE PROPERLY INSULATED.
4
THERMALLY ACTIVATED—BREAKS ON TEMPERATURE
RISE. MAKES ON TEMPERATURE FALL.
CAUTION:
SPECIAL SERVICE CO/ALR SOLDERLESS CONNECTORS MUST
BE USED WHEN CONNECTING WITH ALUMINUM CONDUCTORS;
OTHERWISE, A FIRE HAZARD CAN RESULT.
69-1562–1
L1
(HOT)
L2
1
T410A
L1
4
T1
ELECTRIC
HEATER
M19099
4
CHECK OUT THERMOSTAT
Turn on the power to the heating system.
Turn setting knob all the way clockwise
for clicking sound as switch makes contact. Electric
heater should begin operation.
Turn knob all the way counterclockwise
for clicking sound as switch breaks contact. Electric
heater should shut off.
5
SETTING THERMOSTAT
Begin with setting knob at 70°F (20°C) on the scale.
If this setting is not satisfactory after at least two
hours of operation, turn setting knob upscale to
raise the temperature, or downscale to lower the tempera-
ture. Move knob only a degree each time.
2
; listen
; listen

Advertisement

loading

This manual is also suitable for:

T410b