Before returning the unit to the customer after completion of a
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
Withstanding Voltage Tester
Test voltage
Set time
Set current (Cutoff current)
Unit
Judgment
OK: The "GOOD" lamp lights.
NG: The "NG" lamp lights and the buzzor sounds.
The voltage selector is located on the AC voltage selector box. If adjustment is necessary, use a screwdriver in order to turn the
selector in either direction unitil the correct voltage figure is displayed in the window next the adjustment screw.

AC POWER SUPPLY CORD AND AC PLUG ADAPTOR (FOR QT-CD210W)

QACCA0001SJ00
QACCB0001SJ00
QACCE0001SJZZ
LASER KLASSE 1
LUOKAN 1 LASERLAITE
KLASS 1 LASERAPPARAT
Set value
4,240 VPEAK
3,000 VRMS
6 secs
4 mA

VOLTAGE SELECTION (QT-CD210W ONLY)