Sony DXC-D30WSP Service Manual page 68

Digital video camera
Table of Contents

Advertisement

• Page 1 RESET
(for NTSC)
PAGE 1 (NEXT
PREV
RESET
(YES
)
DEST : UC
EXIT MENU (YES
)
• Page 2 Standing Correction
PAGE 2 (NEXT
PREV
A SHAD
(YES
)
R SHAD
:
118
G SHAD
:
135
B SHAD
:
123
EXIT MENU (YES
)
• Page 3 Flare Adjustment
PAGE 3 (NEXT
PREV
R FLARE
:
0
G FLARE
:
0
B FLARE
:
0
EXIT MENU (YES
)
• Page 4 Pre Knee Setting
PAGE 4 (NEXT
PREV
MPKNEE 1
:
67
MPKNEE 2
:
116
MPKNEE 3
:
164
MPKNEE 4
:
255
RPKNEE
:
128
BPKNEE
:
128
EXIT MENU (YES
)
2-12
(for PAL)
PAGE 1 (NEXT
)
RESET
(YES
)
EXIT MENU (YES
A SHAD (This is not functioned.)
)
R SHAD / G SHAD / B SHAD
Stading correction of V
Standard (correction 0) = 128
Shoot the white portion of pattern box, adjust the UP 4 switch or
DOWN $ switch so that the waveform is flat on the oscilloscope
with VD period.
VA-185 board
R FLARE / G FLARE / B FLARE
)
Flare correction
(Not corrected at 0)
Regarding the adjustment, see the "SECTION 3 ALIGNMENT."
)
MPKNEE1
MPKNEE2
MPKNEE3
MPKNEE4
RPKNEE
BPKNEE
The "RESET" mode is set to standard set
PREV
)
value except each board adjustment
values or differential adjustment values
by each unit. (Refer to table 1.)
* In the NTSC, move the cursor to
"DEST", select UC, then move the
)
cursor to "RESET", and push UP 4
switch.
Test point
CL101 (Rch)
CL201 (Gch)
CL301 (Bch)
Usual Master Pre Knee Point (D range 600 %)
Master Pre Knee point at _3dB gain (D range 425 %) : 116
Master Pre Knee point at FM mode (D range 300 %) : 164
Master Pre Knee point at _3dB gain and FM mode
Rch Pre Knee Point fine Adjustment
Rch Pre Knee Point fine Adjustment
Standard value
: 67
(D range 212 %)
: 255
: 128
: 128
DXC-D30WS/P(E)/V1