Black Balance Adjustment

Correct adjustment of the black balance is important
for optimum operation of a video camera. It is
necessary when using the camera for the first time or
after a significant period out of use, and also when
there has been a sudden change in temperature.
The adjustment value is saved in memory, and
readjustment is not normally necessary after powering
the camera off or simply when lighting conditions
change.
2
1
1
Move the POWER switch to the ON SAVE
position, and check that the OUTPUT/DL/DCC+
switch is in one of the CAM positions.
2
Push the WHT/BLK switch in the BLK direction
and release.
The lens iris closes, and black balance adjustment
is carried out.
During the adjustment the legend "AUTO BLACK
-OP-" appears in the viewfinder.
AUTO
BLACK
-OP-
After a few seconds the adjustment is complete,
and the legend in the viewfinder changes to
"AUTO BLACK -OK-".
74
Chapter 5 Adjustments and Settings
Notes
• When using a camera control unit, if the W/B
BALANCE switch of the camera control unit is set to
MANUAL, it is not possible to carry out black
balance adjustment on the camera.
• When using a CCU-M5/M5P Camera Control Unit,
make sure that the MODE switch of the CCU-M5/
M5P is in the CAM position.
If black balance adjustment cannot be
completed automatically
The warning message "AUTO BLACK -NG-" appears
in the viewfinder.
Make the necessary corrections, then carry out the
process again.
Warning messages for black balance adjustment
Message
Meaning and corrections to be made
AUTO BLACK
The lens iris did not close fully.
-NG-
Check whether the lens cable is
connected properly, and whether there is
:
IRIS
a fault in the lens. If a second attempt to
NOT CLOSED
carry out the adjustment fails, consult
TRY AGAIN
your Sony dealer.
AUTO BLACK
The iris opened during adjustment or
there is a hardware error.
-NG-
Close the iris and try again. If this fails,
:
??
consult your Sony dealer.
TRY AGAIN
BARS
The camera is outputting a color bar
signal.
Move the OUTPUT/DL/DCC+ switch to
one of the CAM positions.

Shutter Settings

This section covers the settings for electronic shutter
speed, CLS (clear scan ) and EVS function.
The new value for the shutter speed or clear scan
frequency and EVS setting remains set until changed,
even when the camera is powered off.
Shutter speeds
There are five shutter speeds, from
1
/
s (DXC-D30)
100
1
1
or
/
s (DXC-D30P) to
/
s. Increasing the shutter
60
2000
speed reduces blurring when shooting a fast-moving
subject. It is also possible to reduce flicker when
shooting under fluorescent lighting by changing the
shutter speed.
CLS (Clear Scan) function
When shooting a computer screen or projected image,
horizontal bands may appear in the camera image.
This is because the vertical scan frequency of the
computer-generated image is different from the
vertical scan frequency of the video system. The clear
scan function allows you to select a vertical scan
frequency to reduce this interference.
EVS (Enhanced Vertical Scan)
This function enhances the vertical scan resolution
from 400 to 450 lines (or 450 to 530 lines) to reduce
flicker. However, this increases the aliasing.
Setting the shutter speed, CLS and EVS
function
Notes on setting the shutter speed
• The faster you make the shutter speed, the darker the
image becomes. Check the brightness in the
viewfinder, and if necessary increase the lighting
level or adjust the iris.
• When the shutter speed is very fast, shooting a high
intensity subject may cause long vertical tails to
appear on the highlights (smear).
Note on setting the CLS function
The vertical scan frequencies of computer screens
vary, and it may not be possible to eliminate the
interference patterns entirely. Note also that the
vertical scan frequency may change depending on the
software being run.
1
3
2
1
Set the SHUTTER switch to the ON position.
The SHUTTER indicator in the viewfinder comes
on, and it is now possible to change the shutter
speed or clear scan frequency setting and to set the
EVS function. (If the EVS is already selected, the
SHUTTER indicator will not light.)
2
Operate the MENU/STATUS switch to align the
cursor with the item "SHUTTER" in basic menu
page 1.
A.IRIS:±0
DTL LEV: ±0
M.BLACK:±0
STRETCH:±0
mSHUTTER:1/250
3
Press the UP/ON button or DOWN/OFF button to
select the required shutter speed, scan frequency or
EVS.
Each time you press the UP/ON button or DOWN/
OFF botton, the shutter speed or clear scan
frequency setting changes in the following order:
DXC-D30
1/100
(Value when
1/250
1/500
1/1000
1/2000
EVS
shipped)
1/60
DXC-D30P
DXC-D30
200.3Hz
60.4Hz
• • •
201.4Hz
50.3Hz
• • •
DXC-D30P
75
Chapter 5 Adjustments and Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxc-d30wsDxc-d30wslDxc-d30wspl

Table of Contents