Snmp Commands - Configuration Level - HP Procurve 2524 Cli Reference Manual

Hp network interface device user manual
Table of Contents

Advertisement

2.12.2 SNMP commands – Configuration Level
[no] snmp-server community <community-name>
[manager | operator]
[restricted | unrestricted]
Used to configure a new SNMP community or to edit the configuration for an
existing one
Parameters:
 <community-name> - Enter (up to 16 characters) the SNMP community name.
 [manager | operator] - Manager - the community can access all MIB objects;
Operator - the community can access all except the CONFIG MIB.
 [restricted | unrestricted] - Unrestricted - any MIB variable that has read/write
access can be set; Restricted - MIB variables cannot be set, only read.
[no] snmp-server host <ip-addr> <community-name> [none | all | non-info | critical |
debug]
Configures which network management stations will receive SNMP event log
messages from the switch and the types of events for which the switch will send
these messages.
Parameters:
 <ip-addr> - Address of the network management station.
 <community-name> - The name of the SNMP community to which the network
management station belongs.
 [none | all | non-info | critical | debug] - The level of Switch events that will
generate a Trap to be sent: None - send no log message; All - send all log
messages; Not INFO - send each log message that is not informational-only;
Critical - send critical-level log messages; Debug (reserved for Internal use).
[no] snmp-server enable traps authentication
Enables authentication traps to be sent when a management station attempts an
unauthorized access.