Replacing An Online Physical Disk; Restrictions And Limitations; Stopping Background Initialization - Dell PowerEdge H730P User Manual

Raid controller (perc) for dell poweredge r920 systems
Table of Contents

Advertisement

4.
Press the down-arrow key to select Remove Hot Spare from the list of actions and press <Enter>.
The physical disk is changed to the Ready state. The status of the physical disk is displayed under the
heading State.
NOTE: Try to use physical disks of the same capacity in a specific virtual disk. If you use physical
disks with different capacities in a virtual disk, all physical disks in the virtual disk are treated as if
they have the capacity of the smallest physical disk.
NOTE: To remove additional global or dedicated hot spares, follow step 1 to step 4.

Replacing An Online Physical Disk

In addition to the automatic Replace Member operation, you can manually replace any physical disk that
is part of a virtual disk using the Replace Member functionality.
Perform the following steps to replace a physical disk:
1.
In the Virtual Disk Management window, select Virtual Disk # and press the down-arrow key until
Physical Disks is highlighted.
2.
Press the right-arrow key to expand the list of physical disks that are members of the virtual disk.
3.
Press the down-arrow key and highlight the desired physical disk you want to replace. Press <F2> to
expand the list of allowed operations on the disk.
4.
Select Replace.
5.
Select Start.
6.
Press the down-arrow to highlight a replacement disk and then press the spacebar to select the disk.
7.
Select OK to start the replacement.
NOTE: The replacement disk must be a hot spare or an unconfigured disk without a foreign
configuration. It must have the same or greater capacity and should be of the same type as the
disk it is replacing.

Restrictions and Limitations

The following restrictions and limitations apply to the Replace Member operation:
The Replace Member functions are restricted to one per array for RAID 0, RAID 1, and RAID 5, and two
per array for RAID 6.
The Replace Member function and rebuild cannot run simultaneously on a RAID 6 virtual disk. The
rebuild operation has a higher priority, and the Replace Member operation is aborted if a rebuild
begins.
The Replace Member function and rebuild cannot run simultaneously on a RAID 6 virtual disk. The
rebuild operation has a higher priority, and the Replace Member operation is aborted if a rebuild
begins.

Stopping Background Initialization

Background initialization (BGI) is the automated operation in which parity is created and written. BGI does
not run on RAID 0 virtual disks. Under certain conditions, the BIOS Configuration Utility (<Ctrl> <R>)
displays a message if you want to stop a BGI in progress. An alert message is displayed if a BGI is in
progress and you start any of the following actions:
A Full Initialization on the virtual disk
A Fast Initialization on the virtual disk
A Consistency Check on the virtual disk
The following alert message is displayed: