Grounding guidelines

Electrostatic discharge damage

Electronic components are sensitive to electrostatic discharge (ESD). Circuitry design and structure
determine the degree of sensitivity. Networks built into many integrated circuits provide some protection,
but in many cases, ESD contains enough power to alter device parameters or melt silicon junctions.
A discharge of static electricity from a finger or other conductor can destroy static-sensitive devices or
microcircuitry. Even if the spark is neither felt nor heard, damage may have occurred.
An electronic device exposed to ESD may not be affected at all and can work perfectly throughout a
normal cycle. Or the device may function normally for a while, then degrade in the internal layers,
reducing its life expectancy.
CAUTION:
components, observe these precautions:
Keep components in their electrostatic-safe containers until you area ready to install them.
Use nonmagnetic tools.
Before touching an electronic component, discharge static electricity by using the guidelines described in
this section.
Avoid touching pins, leads, and circuitry. Handle electronic components as little as possible.
If you remove a component, place it in an electrostatic-safe container.
The following table shows how humidity affects the electrostatic voltage levels generated by different
activities.
CAUTION:
Event
Walking across carpet
Walking across vinyl floor
Motions of bench worker
Removing DIPS from plastic tube
Removing DIPS from vinyl tray
Removing DIPS from Styrofoam
Removing bubble pack from PCB
Packing PCBs in foam-lined box
To prevent damage to the computer when you are removing or installing internal
A product can be degraded by as little as 700 V.
Typical electrostatic voltage levels
Relative humidity
10%
40%
35,000 V
15,000 V
12,000 V
5,000 V
6,000 V
800 V
2,000 V
700 V
11,500 V
4,000 V
14,500 V
5,000 V
26,500 V
20,000 V
21,000 V
11,000 V
Preliminary replacement requirements
55%
7,500 V
3,000 V
400 V
400 V
2,000 V
3,500 V
7,000 V
5,000 V