• If the fixing bracket is near to the termi-
nal block, always make sure the con-
nection cable does not come in contact
with the edge of the bracket.
• Prevent damage of the cut surfaces of
the worktop against moisture with a
correct sealant!
• Seal the appliance to the worktop with
no space left with a correct sealant.
• Prevent damage of the bottom of the
appliance from steam and moisture,
e.g. from a dishwasher or oven.
• Do not install the appliance adjacent to
doors and below windows. Hot cook-
ware can be hit off the hob when you
open doors or windows.
• Disconnect the appliance from the
electrical supply, before you do
maintenance work or cleaning.
WARNING!
Risk of injury from electrical cur-
rent. Carefully obey the instruc-
tions for electrical connections.
• The electrical mains terminal is live.
• Make the electrical mains terminal free
of voltage.
• Install correctly to give anti-shock pro-
tection.
• Loose and incorrect mains plug and
socket connections can make the ter-
minal become too hot.
• A qualified electrician must install the
clamping connections correctly.
• Use a strain relief clamp on cable.
• Use the correct mains connection cable
and replace the damaged mains cable
with the proper cable type. Speak to
your local Service Centre.
The appliance must have the electrical in-
stallation which lets you disconnect the
appliance from the mains at all poles with
a contact opening width of minimum 3
mm. You must have correct isolation devi-
ces: line protecting cut-outs, fuses (screw
type fuses removed from the holder),
ground leakage trips and contactors.
The manufacturer is not responsible
for any injury to persons and pets or
damage to property caused by failure
to obey these requirements.

8.2 Electrical connection

• Ground the appliance according to
safety precautions.
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug, able to support the load
marked on the rating plate. The plug
has to be fitted in a correct socket.
• Any electrical component must be in-
stalled or replaced by the Service Force
Centre technician or qualified service
personnel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to
the mains plug after installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extension cable, an adapter or
a multiple connection (risk of fire).
Check that the ground connection is in
conformity with the standard and regu-
lations force.
• The power cable must be placed in
such a way that it does not touch any
hot part.
• Connect the appliance to the mains
with a device that lets to disconnect the
appliance from the mains at all poles
with a contact opening width of mini-
mum 3 mm, eg. automatic line protect-
ing cut-out, earth leakage trips or fuse.
• None of a parts of the connection cable
can not get a temperature 90 °C. The
blue neutral cable must be connected
to the terminal block label with "N". The
brown (or black) phase cable (fitted in
the terminal block contact marked with
"L") must always be connected to the
live phase.
8.3 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
ENGLISH