8.10

Error message on screen

The meaning of the error message is explained in the documentation for the
relevant components and programs on the Fujitsu manuals server.
8.11
Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.
8.12

Temperature warning

A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message.
The above log is output or the above notification is issued by ServerView when
the ambient temperature exceeds the upper limit of the temperature
boundaries. The upper limit is 35°C for standard server and 40°C with Cool-
®
safe
Advanced Thermal design.
Ê Although continued use within the temperature boundaries poses no
problems within itself, reconsider the surrounding environment conditions if
this log is output or if ServerView issues this notification.
8.13

No effect of keyboard or mouse

Typing the keyboard does not display any characters, or the mouse cursor does
not move.
Ê Check to see whether the keyboard and mouse are connected properly. If
they are not connected or you replaced them yourself, then connect the
cables to the server.
RX100 S8