Checking The Blades; Removing The Bioclip Plug - Husqvarna Rider 316T Operator's Manual

Hide thumbs Also See for Rider 316T:
Table of Contents

Advertisement

Checking the blades

To achieve the best mowing results it is important that the
blades are undamaged and well-sharpened.
Check that the blades' attachment screws are tight.
IMPORTANT INFORMATION Replacing or sharpening the
blades should be conducted by an authorised service
workshop.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles
that result in a breakdown. Let the service centre assess
whether the blade can be sharpened or must be replaced.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.
Combi 103, Combi 112
1 Put the unit in the service position, see Placing in the
service position.
2 Remove the three screws holding the BioClip plug, and
remove the plug.
3 Tip: Fit three full-thread screws M8x15 mm in the screw
holes to protect the threads.
4 Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
28 –
English
Maintenance
Combi 94
1 Put the unit in the service position, see Service position
for the cutting unit.
2 Loosen the knob and the bolts holding the BioClip plug
and remove the plug.
3 Replace the unit in normal position.