GE RAK148D1 Owner's Manual & Installation Instructions page 9

Digital non-programmable thermostats
Hide thumbs Also See for RAK148D1:
Table of Contents

Advertisement

3. Temperature Differential—Stage
2—(RAK148D1 only) (1–9°F)
(1–5°C)—Set the number of
degrees between when stage 1
turns on and stage 2 turns on.
Press the
Press the SW6 button to advance to the next screen.
4. Minimum Cool Setpoint (60, 64,
66, 68, 70, 72, 74, 76°F) (15, 17, 19,
20, 21, 22, 23, 24°C)
Adjust to control the minimum Cool set temperature allowed.
Press the
Press the SW6 button to advance to the next screen.
5. Maximum Heat Setpoint (65, 70,
72, 74, 76, 78, 80, 85°F) (18, 21, 22,
23, 24, 26, 27, 29°C)
Adjust to control the maximum Heat set temperature allowed.
Press the
Press the SW6 button to advance to the next screen.
6. Room temperature offset (+9°F to
–9°F) (+5°C to –5°C)
Adjust to calibrate displayed room
temperature to match actual room temperature.
Press the
Press the SW6 button to advance to the next screen.
or
button to set differential value.
or
button to select.
or
button to select.
or
button to select.
9