Controlling The Multiple Product; Connecting The Cable; Rs-232C Configurations; Communication Parameter - LG 32LS33A Owner's Manual

Monitor signage
Hide thumbs Also See for 32LS33A:
Table of Contents

Advertisement

CONTROLLING THE MULTIPLE PRODUCT

Use this method to connect several products to a single PC. You can control several products at a
y
y
time by connecting them to a single PC.
In the Option menu, Set ID must be between 1 and 255 without being duplicated.
y
y

Connecting the Cable

Connect the RS-232C cable as shown in the picture.
The RS-232C protocol is used for communication between the PC and product. You can turn the
y
y
product on/off, select an input source or adjust the OSD menu from your PC.
Monitor 4

RS-232C Configurations

8-Wire Configurations (Cross-over RS-232C cable)
PC
DCD
1
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9 D-Sub 9
(Female) (Female)

Communication Parameter

Baud Rate : 9600 BPS
y
y
Data Length : 8 bit
y
y
Parity Bit : None
y
y
Stop Bit : 1bit
y
y
Flow Control : None
y
y
Communication Code : ASCII code
y
y
Use a crossed (reverse) cable
y
y
Monitor 3
Monitor 2
Set
1
DCD
3
TXD
2
RXD
5
GND
6
DSR
4
DTR
8
CTS
7
RTS
CONTROLLING THE MULTIPLE PRODUCT
Monitor 1
RS-232C Cable (not included)
NOTE
When using 3-wire connections (non-
y
y
standard), an IR daisy chain cannot be used.
63