Diagnostic Error Code
015-036-XXX
USB port Register error
015-040-XXX
USB port IRQ failure
015-195-XXX
USB port Test aborted by user
015-196-XXX
USB port test halt, error threshold exceeded
015-197-XXX
USB port test warning
015-198-XXX
USB port test aborted
015-199-XXX
USB port test failed, cause unknown
018-000-XXX
PCI Card Test Passed
018-0XX-XXX
PCI Card Failure
018-195-XXX
PCI Card Test aborted by user
018-196-XXX
PCI Card test halt, error threshold exceeded
FRU/Action
System board
1. Run setup and check for conflicts
2. Flash the system. See "Flash update
procedures" on page 205
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Flash the system and re-test. See "Flash
update procedures" on page 205
3. Go to "Undetermined problems" on page
81
1. Go to "Undetermined problems" on page
81
2. Flash the system and re-test. See "Flash
update procedures" on page 205
3. Replace component under function test
No action
1. Riser card, if installed
2. System board
1. PCI card
2. Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file