Decode Session Timeout

Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from
D, Numeric Bar Codes
For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and
5 bar codes. To correct an error or change the selection, scan Cancel on
NOTE The Decode Session Timeout cannot be less than or equal to either
Symbol
Decode Session Timeout

Timeout Between Decodes, Same Symbol

Parameter # 89h
Use this option in presentation mode and Continuous Bar Code Read to prevent the beeper from continuously
beeping when a symbol is left in the digital scanner's field of view. It is programmable in 0.1 second increments
from 0.0 to 9.9 seconds. The default interval is 0.3 seconds.
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric
bar codes from
Appendix D, Numeric Bar Codes
increments.
NOTE The Timeout between Decodes, Same Symbol cannot be greater than or equal to the
Timeout.
that correspond to the desired on time. Enter a leading zero for single digit numbers.
or
Timeout Between Decodes, Different
User Preferences & Miscellaneous Options 4 - 23
page
Symbols.
that correspond to the desired interval, in 0.1 second
Timeout Between Decodes, Same Symbol
Appendix
D-2.
Timeout Between Decodes, Same
Decode Session