Clsi Editing; Notis Editing - Motorola DS9208-1D Product Reference Manual

Digital
Table of Contents

Advertisement

9 - 50 DS9208-1D Product Reference Guide

CLSI Editing

Parameter # 36h
Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth
characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.
NOTE Symbol length does not include start and stop characters.
Enable CLSI Editing

NOTIS Editing

Parameter # 37h
Enable this parameter to strip the start and stop characters from a decoded Codabar symbol. Enable this
feature if the host system requires this data format.
Enable NOTIS Editing
(01h)
(01h)
*
Disable CLSI Editing
(00h)
*
Disable NOTIS Editing
(00h)