Builder series non-programmable thermostats single stage heat / cool conventional and heat pump multi-stage 2 heat / 1 cool conventional and heat pump

Advertisement

Builder Series
Non-Programmable Thermostats
MODEL
1000, 1000NC
MODEL
1200, 1200NC
Before Installing, Programming or Operating,
PLEASE READ ALL INSTRUCTIONS
Specifications
1
Installation
2
Testing Your New Thermostat
3
Programming User Settings
4
Temperature Adjustment
5
WARNING
Important Safety Information
• Always turn off power to the air conditioning or heating system prior to
installing, removing, cleaning or servicing thermostat.
• This thermostat requires either 24 Volts AC Power or two (2) properly installed
"AA" alkaline batteries for normal operation and control of the heating or
cooling system. Refer to "Low Battery Detection and Replacement" section for
more information.
• This thermostat should only be used as described in this manual. Any other
use is not recommended and will void the warranty.
1
Specifications
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals) (Model 1000, 1000NC)
3 amp total maximum load (all terminals) (Model 1200, 1200NC)
• Control Range: 45˚ - 90˚ F (7˚- 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volt AC
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
• Model 1000, 1000NC: Compatibility with low voltage single stage gas, oil or
electric heating or cooling systems, including single stage heat pumps, can
also be used on 250mv to 750mv millivolt heating only systems.
Single Stage Heat / Cool
Conventional and Heat Pump
Multi-Stage 2 Heat / 1 Cool
Conventional and Heat Pump
Additional Operation
6
Features
Battery Replacement
7
Troubleshooting
8
Wiring Diagrams
9
1
Specifications
• Model 1200, 1200NC: Compatibility with low voltage multi-stage gas, oil or
electric heating or cooling systems, including multi-stage heat pumps.
• Terminations, Model 1000, 1000NC: Rc, Rh, B, O, Y, W, G, C
• Terminations, Model 1200, 1200NC: R, O, B, C, Y1, E/W1, G, W2
2
Installation
Replacing Existing Thermostat
Most thermostats have three parts:
• The cover, which may snap or hinge over the existing thermostat.
• The electronics or body, which controls the existing system.
• The sub-base, where the wires attach through the wall to the existing system.
1. Always turn off power to the air conditioning or heating system prior to
removing existing thermostat.
2. Carefully remove the cover and electronics body from the old thermostat sub-base.
Depending on the brand, these parts may pull off or need to be unscrewed. The
old sub-base should remain wired and on the wall until steps 4 and 5.
3. Label every old wire with the letter of the connection to which the wire is
attached. Example letters are R, M, Y etc. Depending on the brand of the old
thermostat, your letters may be different.
4. After labeling the old wires, loosen each connection and remove them from old
sub-base. Secure the wires to prevent them from slipping into the hole in the wall.
5. Remove the old sub-base from the wall, again being careful that the wires do
not slip into the hole in the wall.
6. Use the chart below to determine the new thermostat connections. As an
example, if the old thermostat had a G connection, it goes to G on the new
thermostat. Note the chart includes information for Braeburn
1200(NC) thermostats. Be sure to use the correct column for the new thermostat.
Old Terminal from
New Terminal for
Existing Thermostat
New Thermostat
(1000, 1000NC)
V or Rc
Rc
M, 4, Rh, or R
Rh
R, V-VR or VR-R
B
B
O
O
Y, Y1 or M
Y
E, H, W, or 4
W
G or F
G
C, X or B
C
cont.
1000(NC) and
®
New Terminal for
Terminal
New Thermostat
Description
(1200, 1200NC)
Cooling
Transformer
Heating
Transformer
R
24 VAC
B
Reversing Valve
(Heating)
O
Reversing Valve
(Cooling)
Y1
Cooling or
Compressor for
HP System
E/W1
1st Stage Heat
or Emergency Heat
G
Fan Control
C
24 VAC Common
1

Advertisement

loading

Summary of Contents for Braeburn Builder 1000

  • Page 1 • Model 1200, 1200NC: Compatibility with low voltage multi-stage gas, oil or Builder Series electric heating or cooling systems, including multi-stage heat pumps. • Terminations, Model 1000, 1000NC: Rc, Rh, B, O, Y, W, G, C Non-Programmable Thermostats • Terminations, Model 1200, 1200NC: R, O, B, C, Y1, E/W1, G, W2...
  • Page 2: Installation

    Installation cont. cont. NOTE–MODEL 1000, 1000NC: This thermostat is designed for use with 24 18. Open front thermostat door and open battery compartment door. Volt-AC low voltage single stage gas, oil or electric heating or cooling systems, 19. Install two new "AA" alkaline batteries. Locate the positive (+) ends of the...
  • Page 3: Programming User Settings

    The entire display will flash once and the SET indicator will be flashing. Release the or button and press NOTE–MODEL 1000, 1000NC: Once you have finished setting the first stage the or button again to adjust the set temperature. differential, you can wait 5 seconds and the thermostat will return to the normal operating mode.
  • Page 4: Additional Operation Features

    Additional Operation Features Additional Operation Features cont. Status Indicators Compressor Protection Feature HEAT: This will turn on whenever the system switch This thermostat includes an automatic compressor protection feature to avoid is in the HEAT mode. “HEAT” will flash when the potential damage to the system from short cycling.
  • Page 5: Wiring Diagrams

    See Section 7. If AC power is present, call a professional service technician to verify thermostat and system performance. MODEL 1000, 1000NC: Single Stage Conventional Systems (Single Transformer) Symptom: HI is shown in the thermostat display. Potential Solution: The temperature sensed by the thermostat Rc Rh is higher than the 99˚...
  • Page 6 Wiring Diagrams Wiring Diagrams cont. cont. See NOTE 2 MODEL 1200, 1200NC: Multi-Stage Heat Pump Systems MODEL 1000, 1000NC: Single Stage Heat Pump System Rc Rh E/W1 Factory Installed Jumper Reversing Valve (Active in Reversing Valve Emergency 2nd Stage Cooling - See...
  • Page 7: Limited Warranty

    Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction.