IV. SERVICE DIAGNOSIS

1. NO ICE PRODUCTION

PROBLEM
[1] The icemaker
a) Power Supply
will not start
b) Fuse (Inside Fused
c) Control Switch
d) Bin Control
Thermostat
For mechanical
bin control,
see "II. 4. [c]"
e) High Pressure
Control
f) Transformer
g) Wiring to
Controller Board
h) Thermistor
i) Hot Gas Solenoid
Valve
j) Water Supply Line
k) Water Solenoid
POSSIBLE CAUSE
1. "OFF" position.
2. Loose connections.
3. Bad contacts.
4. Voltage too high.
1. Blown out.
Disconnect, if any)
1. "OFF" position.
2. Bad contacts.
1. Tripped with bin filled
2. Ambient temperature
3. Set too warm.
4. Bulb out of position.
5. Bad contacts or leaks
1. Bad contacts.
1. Thermal fuse blown out
1. Loose connections or
1. Leads short-circuit or
1. Continues to open in
1. Water supply off and
2. Condenser water
1. Mesh filter or orifice gets
2. Coil winding opened.
3. Wiring to Water Valve.
with ice.
too cool.
bulb.
or coil winding opened.
open.
open and High
Temperature Safety
operates.
freeze cycle and High
Temperature Safety
operates.
water supply cycle does
not finish.
pressure too low or off
and Pressure Control
opens and closes fre-
quently to finally operate
High Temperature Safety.
clogged and water supply
cycle does not finish.
84
REMEDY
1. Move to "ON" position
2. Tighten
3. Check for continuity and
replace.
4. Check and get
recommended voltage.
1. Check for short circuit
and replace
1. Move to "ICE" position.
2. Check for continuity and
replace.
1. Remove ice.
2. Increase ambient
temperature.
3. See "II.2.[d]
CONTROLS AND
ADJUSTMENTS, 5) Bin
Control."
4. Place in position.
5. Check for continuity and
replace.
1. Check for continuity and
replace.
1. Replace.
1. Check for continuity and
replace.
1. See "II.2.[d] CONTROLS
AND ADJUSTMENTS, 1)
Defrost Control."
1. Check for power off in
freeze cycle and replace.
1. Check and get
recommended
pressure.
2. Check and get
recommended
pressure.
1. Clean.
2. Replace.
3. Check for loose
connection or open, and
replace.