Check Operation - KitchenAid 30" Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

3. Remove vent box knockout and install a UL listed or CSA
approved conduit connector. Feed exterior-mounted vent
motor wiring through conduit connector.
A
B
C
A. Green or green and yellow ground wires
B. Green ground screw
C. Blue wires
D. UL listed wire connector
E. Brown wires
F. Downdraft vent wiring
G. Black wires
H. White wires
I. UL listed or CSA approved conduit and connector,
(Home power supply cable).
J. UL listed or CSA approved conduit and connector,
(Exterior-mounted vent motor wiring).
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.
4. Attach the green (or green and yellow) ground wires from the
home power supply cable and the exterior-mounted vent
motor wiring to the green ground screw.
IMPORTANT: Exterior vent motor wires must be connected in
the terminal box as shown.
5. Connect the 2 blue wires together using UL listed wire
connectors.
6. Connect the 2 brown wires together using UL listed wire
connectors.
7. Connect the 2 white wires together using UL listed wire
connectors.
8. Connect the 2 black wires together using UL listed wire
connectors.
9. Tighten conduit connector clamp screws.
10. Replace the terminal box cover and secure with screw.
11. Reconnect power.
20
J
I
H
G
F
E
D

Check Operation

1. Push and hold the button on the top of the downdraft vent for
a few seconds. The retractable section of the downdraft vent
will rise. The blower will start immediately if the blower control
knob is set to an "on" position.
2. Position the top trim over the retractable section and snap
trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
For information on ordering, see the "Assistance or Service"
section.
A
E
A. Top trim
B. ON/OFF button
C. Blower control slider
D. End cap
E. Filter or filters depending on model
3. Slide the control slider on the side of the vent to check the
speed of the blower.
If the blower does not operate:
Check that filter or filters are pressed in as far as they
will go.
Check that circuit breaker has not tripped or a household
fuse blown.
Check downdraft vent fuse located under power board.
4. Connect vent system to 10" (25.4 cm) round vent collar plate.
Position vent to avoid wall studs and floor joists. Complete all
vent work. Use clamps to seal all joints.
Vertical vent for wall-mounted installations should pitch down
slightly toward the vent to allow moisture to run outside.
5. Install cooktop according to manufacturer's instructions.
Check that rear of cooktop overlaps edge of retractable
downdraft vent by ³⁄₈" (9.5 mm). See "Countertop Cutout
Dimensions" in the "Location Requirements" section.
NOTE: To get the most efficient use from your new retractable
downdraft vent, read the "Vent System Use" section.
B
C
D

Advertisement

Table of Contents
loading

This manual is also suitable for:

36"

Table of Contents