Powered Hand Tool; Replacing Belt; Thermal Protector - Hoover WindTunnel WindTunnel Upright Bag Vacuum Cleaner Owner's Manual

Hoover windtunnel upright bag vacuum cleaner owner's manual
Table of Contents

Advertisement

3 - 2 2
B
7. Replace belt guard (B) making sure
not to pinch brush bristles in guard. Tur n
agitator making sure it rotates freely.
Replace and tighten screws.

Powered hand tool

Belt replacement
Inspecting the belt
The powered hand tool belt is designed
to last a long time and is not normally
replaced. However, if the belt is
cracked, gouged or broken, it should be
replaced.
3 - 2 4
The belt can be seen through the top of
the nozzle or by removing the bottom
plate and belt guard (Figs. 3-18 and 3-
19).
Lubrication
The motor is equipped with bearings
that contain sufficient lubrication for the
life of the motor. The addition of lubri-
cant could cause damage. Therefore,
do not add lubricant to motor bear-
ings. The agitator is equipped with two
ball bearings that should be lubricated
periodically by a Hoover Factory Service
Center or an Authorized Hoover
Warranty Service Dealer (Depot).
12
3 - 2 3
A
8. To replace bottom plate (A), insert the
four tabs on edge of bottom plate into
slots on front of tool.
Pivot bottom plate down and snap
closed.

Replacing belt

When replacing belt, ask for HOOVER
part No. 38528037.
1. Remove bottom plate, belt guard and
brush roll as described in Figs. 3-18
through 3-20.
3 - 2 5
F
2. Grasp turbine (E) and pull firmly to
remove.
3. Remove belt from turbine pulley (F).
Replace with new belt.

Thermal protector

An internal thermal protector has been
designed into your cleaner to protect it
from overheating.
When the thermal protector activates,
the cleaner will stop running. If this hap-
pens, proceed as follows:
1. Turn the cleaner OFF and disconnect
it from the electrical outlet.
2. Check secondary and final filters for
dirt accumulation.
3. Refer to "Clearing blockages" section.
4. When cleaner is unplugged and the
motor cools for 30 minutes, the thermal
protector automatically resets and clean-
ing may continue.
If the thermal protector continues to acti-
vate after following the above steps, your
cleaner may need servicing (see "Service"
section).
3 - 2 6
E
4. With flat sides of turbine retainers (G)
pointing down, slide retainers into
grooves (H) in tool housing and snap
into place.
5. Replace brush roll, belt guard, and
bottom plate as described in Figs. 3-20
through 3-23.
Service
To obtain approved HOOVER service and
genuine HOOVER parts, locate the near-
est Hoover Factory Service Center or
Authorized Hoover Warranty Service
Dealer (Depot) by:
• checking the Yellow Pages under
"Vacuum Cleaners - Household" OR
• checking the list of Factory Service
Centers provided with this cleaner
OR -
• calling 1-800-944-9200 for an auto
mated referral of authorized service
outlet locations (U.S. only) OR -
• checking the Service section of The
Hoover Company on-line at
www.hoover.com
Do not send your cleaner to The Hoover
Company in North Canton for service,
this will only result in delay.
G
H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Windtunnel u5465-900

Table of Contents