Manual Adjust 2; Auto Adjust; Check - Sony DVP-S300 Service Manual

Hide thumbs Also See for DVP-S300:
Table of Contents

Advertisement

6-6-7. Manual Adjust 2

Manual Adjust 2
SA.000000
SI.00
EMG.00
0. Jitter
on
1. Focus
Offset
xx
2. Tilt
Offset
3. L.F.
Offset
$
30
DVD_SL
12cm
Figure 17
On this screen, manual adjustment can be made where jitter mea-
surement is executed.
0. Jitter
: Turn on/off jitter measurement. Jitter will not
be measured unless the drive runs at CLV.
1. Focus Offset : Adjust focus offset.
2. Tilt Offset
: Adjust tilt offset.
3. L.F. Offset
: Adjust electrical offset in ARP.

6-6-8. Auto Adjust

Auto Adjust
SA.000000
SI.00
EMG.00
0. Auto TRK. Offset
xx xx
1. Auto Tilt Offset
2. Auto Focus Offset
3. Auto Focus Gain
4. Auto TRK. Gain
5. auto EQ
6. Auto L.F. Offset
7. Memorize Pullin
DVD_SL
12cm
Figure 18
On this screen, eacf item can be automaticallyadjusted individu-
ally.
Note, however, that there are some restriction.
0. Auto TRK Offset : Adjust tracking offset automatically. Ad-
justed result is reflected on the EEPROM.
Turn off tracking with the Focus turned on.
Do not execute this at outside track because
pickup moves outside. In the case of CD,
tracking simple AGC is also adjusted here.
1. Auto Tilt Offset
: Adjust tilt offset automatically. Adjusted
result is reflected on the EEPROM. Execute
this with CLVA turned on. If NG, retry this
after focus offset and tangential skew are
adjusted.
2. Auto Focus Offset: Adjust focus offset automatically. Adjusted
result is reflected on the EEPROM. Execute
this with CLVA turned on. If NG, retry this
after tilt offset and tangential skew are ad-
justed.
3. Auto Focus Gain : Adjust focus gain automatically. Adjusted
result is reflected on the EEPROM. Execute
this with CLVA turned on if possible. If
NG, the system will be defective, and re-
pair it.
4. Auto TRK gain
: Adjust tracking gain automatically. Ad-
justed result is reflected on the EEPROM.
Execute this with CLVA turned on if pos-
sible. If NG, the system will be defective,
and repair it.
5. Auto EQ
: Adjust RF equalizer properly. Adjusted re-
sult is not reflected on the EEPROM. Ex-
ecute this with CLVA turned on.
6. Auto L.F. Offset : Adjusts electrical offset in ARP. The ad-
justed value is applied to the EEPROM.
During adjustment, lock the CLV.
7. Memorize Pullin : Sets the pull-in level to the EEPROM.

6-6-9. Check

check
SA.000000
SI.00
EMG.00
1. EEPROM Default set
(set)
6. EEPROM Data
DVD_SL
12cm
Figure 19
On this screen, various checking can be made. Note, however, that
some items such as EEPROM Default set are not recoverable.
1. EEPROM Default set : Use this to set EEPROM set values to
default values. Before executing this, it
is recommended to record current val-
ues.
6. EEPROM data
: Display EEPROM set values list.
Display is made with HEX numbers
“00” – “FF”.
6-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvp-s305Dvp-s315

Table of Contents