VOLTAGE OF EACH CONNECTOR

1. How to measure the voltages on the Main Power Supply PCB in protect mode.
• Since a voltage is applied to the Main Power PCB and PFC PCB heat sinks while the set is operating,
do not touch the heat sinks.
• After the power cord plug was pulled out, do not pull out the connector on the Main Power PCB until
the Green LED (D531: Discharge check LED) turns off.
1) Disconnect CN4, CN10, CN41, CN42, CN49 and CN50
2) Connect pins 1 and 2, 3 and 4 of CN4.
3) Press the power button.
2. On the Main Power Supply PCB. (M00BV)
No.
NAME
1
P5V
3
+14V
10
-8V
No.
NAME
1
Vcc 1
9
Vs
No.
NAME
3
-Vy
4
Vsc
CN352
SPEC.
Ground
5.0V +/- 0.25V
4
14.0V +/- 0.7V
4
-8.0V +/- 0.4V
6
CN41
SPEC.
Ground
5.0V +/- 0.25V
2
180.0V +/- 3.2V
5
CN42
SPEC.
Ground
-165.0V +/- 3.0V
5
120.0V +/- 3.5V
3
No.
NAME
3
+2.5V
6
+3.3V
10
+6.5V
No.
NAME
3
Va
1
Vw
No.
NAME
3
Ve
– 19 –
CN351
SPEC.
Ground
2.5V +/- 0.13V
2
3.3V +/- 0.17V
5
6.5V +/- 0.33V
9
CN50
SPEC.
Ground
65.0V +/- 1.3V
4
170.0V +/- 5.0V
2
CN10
SPEC.
Ground
16.0V +/- 0.4V
4

Hide quick links: