9. Auto RGB Color Balance
9-1. Required Test Equipment
Pattern Equipment: PC Pattern Generator (VG828, VG854,
801GF, MSP3240A)
(16 Gray Scale Pattern output(RGB output Level: 0.7Vp-p)
9-2. Auto RGB Color Balance
(1) Input RGB Source : XGA 60HZ 16 Gray Scale Pattern
(2) Press ADJ KEY on the Service R/C.
(3) Press Vol. + KEY and operate To SET.
(4) Auto-RGB OK means completed adjustment.
(Fig. 12) Auto RGB/ Component Color Balance Test Pattern
10. Auto Adjustment Map(RS-232C)
Type
Baud Rate
Data bit
115200
8
Index
Cmd1 Cmd2
R Gain
j
G Gain
j
Protocol
B Gain
j
Setting
R Offset
j
G Offset
j
B Offset
j
ADJUSTMENT INSTRUCTIONS
RF-043A
RS232
Stop bit
Parity
1
NONE
Data Min Value
Max Value
a
00(00)
b
00(00)
c
00(00)
d
00(00)
e
00(00)
f
00(00)
255(FF)
255(FF)
255(FF)
255(FF)
255(FF)
255(FF)