Pioneer PDP-503PE Service Manual page 5

Pioneer plasma display service manual
Hide thumbs Also See for PDP-503PE:
Table of Contents

Advertisement

PDP-503PE, PDP-503PU
CHARGED SECTION AND HIGH VOLTAGE GENERATING POINT
7 Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In addition,
the measuring equipment can be damaged if it is connected to the
GND of the charged section and the GND of the non-charged
section while connecting the set directly to the commercial AC
power supply. Therefore, be sure to connect the set via an insulated
transformer and supply the current.
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the SW POWER SUPPLY Module)
5. STB Transformer and Converter Transformer
(In the SW POWER SUPPLY Module)
6. Other primary side of the SW POWER SUPPLY Module
SCAN (A)
Assy
SCAN (B)
Assy
Remove the IF Earth Metal (No.14 on the page 25)
beforehand when inclines the power supply unit
as the right figure.
Fig.1 Charged Section and High Voltage Generating Point (Rear View)
4
7 High Voltage Generating Point
The places where voltage is 100V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
1. SW POWER SUPPLY Module ...................................... (225V)
2. X DRIVE Assy .............................................. (–300V to 225V)
3. Y DRIVE Assy ............................................................... (355V)
4. SCAN (A) Assy .............................................................. (355V)
5. SCAN (B) Assy ............................................................... (355V)
6. X CONNECTOR (A) Assy ........................... (–300V to 225V)
7. X CONNECTOR (B) Assy ............................ (–300V to 225V)
Y DRIVE
Assy
SW POWER SUPPLY
Module
AC Inlet with Filter
Power Cord
: Part is Charged Section.
: Part is the High Voltage Generating Points
other than the Charged Section.
Top
Front
X CONNECTOR (A)
Assy
X DRIVE
Assy
X CONNECTOR (B)
Assy
Power Switch
(S1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-503pu

Table of Contents