LITHIUM (+) CONTACT
Fig. 3-15 LITHIUM (+) CONTACT, LITHIUM (-) CONTACT
2.13 LITHIUM (+) CONTACT, LITHIUM (-) CONTACT
(1) LITHIUM (+) CONTACT, LITHIUM (+) LEAD
1. Remove the screw c and remove the LITHIUM (+) CONTACT.
2. Remove soldering and remove the LITHIUM (+) LEAD.
NOTE (Assembling)
After soldering, apply the DIA BOND1663G.
(2) LITHIUM (-) CONTACT, LITHIUM (-) LEAD
1. Remove the screw c and remove the LITHIUM (-) CONTACT.
2. Remove soldering and remove the LITHIUM (-) LEAD.
NOTE (Assembling)
After soldering, apply the DIA BOND1663G.
MAIN FRAME
(1)-1
c
LITHIUM (-) CONTACT
3-15
CHAPTER 3. REPAIR INSTRUCTION
(1)-2
Soldering
NOTE (Assembling)
LITHIUM (+) LEAD
(2)-2
Soldering
NOTE (Assembling)
(2)-1
LITHIUM (-) LEAD
c
c
XA4-9170-407
4.0mm
METAL
M1.7
(SELF TAP)