Apply power to the heating system. Verify the installation by checking
that the heater can be turned On and Off by raising and lowering the
setpoint using the
buttons.
ATTENTION: Keep the thermostat's air vents clean and free from
obstructions at all times.

Temperature Display and Setting

The thermostat normally displays the actual (measured) temperature.
To view the set
temperature (setpoint),
press once on either of
the temperature
adjustment buttons.
To change the setpoint,
press the appropriate
button until the desired
value is displayed.
NOTE: The display is backlit for 10 seconds when either button is
pressed.

Power Outage

The setpoint is stored in non-volatile memory and is not erased when
there is a power outage.

Troubleshooting

PROBLEM
This is normal. Under normal operation, the
Thermostat is hot.
thermostat housing can reach a temperature
between 35 °C (95 °F) and 40 °C (104 °F).
Correct if any the following conditions
applies:
The thermostat is exposed to air draft.
Displayed tempera-
The sticker on the thermostat's screen
ture is wrong.
has not been removed.
The thermostat is located near or above
a heat source such as a light dimmer.
The thermal protection device on the heater
Display disap-
was temporarily opened. This can happen if
pears and reap-
the heater is obstructed by furniture or curtain
pears after a few
and has overheated, or if the heater's thermal
minutes.
protection device is too sensitive.
Display looks faded
The heating system is less than the required
when heating is
minimum load. This thermostat cannot be
activated.
used below that rating.
RLV3100
Appears
when the
setpoint is
displayed
Heating power
indicator
SOLUTIONS

Specifications

- Supply: 240 VAC, 50/60 Hz
- Minimum load: 500 W (2 A resistive only)
- Maximum load: 3000 W (12.5 A resistive only)
- Display range: 0 to 50°C (32 to 122°F)
4.
- Setpoint range: 5 to 30°C (40 to 85°F)
- Resolution: 0.5°C (1°F)
- Storage: -20 to 50°C (-4 to 120°F)
- Dimensions: 126 x 121 x 31 mm (5.0 x 4.8 x 1.2 inches)
- Approval: c UL us
Warranty
Honeywell warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and
service, for a period of one (1) year from the date of purchase by the
consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, Honeywell shall repair or
replace it (at Honeywell's option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it, or
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer
5.
Care will make the determination whether the product should be
returned to the following address: Honeywell Return Goods,
Dock 4 MN10-3860, 1885 Douglas Dr N, Golden Valley, MN
55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This
6.
warranty shall not apply if it is shown by Honeywell that the defect or
malfunction was caused by damage which occurred while the
product was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the
product within the terms stated above. HONEYWELL SHALL NOT
BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH
OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER
FAILURE OF THIS PRODUCT. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS
WARRANTY
HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF
ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY
PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION
OF THIS WARRANTY. Some states do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply
to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from state to state.
If you have any questions concerning this warranty, please write
Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN
55422 or call 1-800-468-1502. In Canada, write Retail Products
ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive,
Scarborough, Ontario M1V4Z9.

Customer assistance

If you have any questions about the operation of your thermostat,
please go to http://yourhome.honeywell.com, or call Honeywell
Customer Care toll-free at 1-800-468-1502.