Installer Setup; Temperature Settings - Honeywell Chronotherm IV T8602C Installation Instructions Manual

Deluxe programmable thermostats
Table of Contents

Advertisement

Temperature Settings

Refer to Table 2 for the default program. If the daytime
energy savings period is not used, press the period key
(Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models. See
Owners Guide, form number 69-0940, for complete
instructions on changing the program.
Table 2. Default Program Settings.
Period
Time
Wake
6:45 AM
Leave
8:45 AM
Return
5:00 PM
Sleep
10:00 PM

INSTALLER SETUP

NOTE: For most applications, the thermostat factory-
settings will not need to be changed. Review
the factory settings in Table 2 and if no
changes are necessary, go to the Installer Self-
Test section.
The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, system changeover and outdoor
temperature display. Installer Setup numbers are listed
in Table 3. The table includes all the configuration
options and the factory-settings for the T8602.
A combination of key presses are required to use the
Installer Setup feature.
— To enter the installer setup, press and hold the
information i key with the increase
decrease
keys until the first number is displayed.
All display segments appear for approximately
three seconds before the number is displayed. See
Fig. 8 and 9.
— To advance to the next Installer Setup, press the
Time
key.
— To change a setting, use the increase
decrease
key.
— To scroll the Installer Setup numbers backwards,
press the Time
key.
— To exit the Installer Setup, press Run Program.
T8602C CHRONOTHERM
Heat
Cool
Setpoint
Setpoint
20°C
25°C
4.5°C
37°C
20°C
25°C
4.5°C
37°C
and
or
®
IV DELUXE PROGRAMMABLE THERMOSTATS
Wait
Set Program
Recovery
Hold for
Filter
Em Ht
Mon
Tue Wed Thu Fri Sat Sun
Wake Leave Return Sleep
Fig. 8. Display of all the segments of the LCD.
Fan
Setting
Auto
Auto
Auto
Auto
Fig. 9. Display of Installer Setup number and setting.
CAUTION
Electric heat systems must be configured to 1 in
Installer Setup number 2 to prevent equipment
damage caused by the system running without
the fan.
IMPORTANT
Only configurable numbers are shown on the
device. Example: If thermostat does not have a
system key, Installer Setup Number 12 will not
be displayed. Review Table 3 factory-settings
and mark any desired changes in the Actual
Setting column. When Installer Setup is
complete, review the settings to confirm that
they match the system.
5
Set Day/Time
Temporary Setting
AM
PM
Aux Ht
Days
Repl Batt
Room
Heat
DST
FACTORY SETTING OR OTHER
INSTALLER SETUP
CHOICE DISPLAY (COLUMN 3
NUMBER DISPLAY
OR 5 OF TABLE 3)
(COLUMN 2 OF TABLE 3)
System
Em Heat
Off
Cool
Auto
Fan
Outdoor
On
Cool
Auto
M14559
M14618
69-1567

Hide quick links:

Advertisement

Table of Contents
loading