3.

Adjustment of Home Position Detector

3-1. Measuring Gap Between Home Position Detector and Frame

(1)
Remove the printer cover [1].
(2)
Measure gap between home position detector [2] and frame [3].
(3)
The standard gap value is 3.8 0.3 mm.
(4)
If the gap does not lie within this range, adjust it by following the procedure in item 3-2.
Fig. 3-7 Position of Home Position

3-2. Adjusting Gap Between Home Position Detector and Frame

If the gap does not lie within the standard range, adjust it by carrying out the following procedures.
(1)
Remove the upper case according to procedures described in chapter 4.
(2)
Loosen the four screws [4].
(3)
Move the printer mechanism.
(4)
Insert the thickness gauge (3.8 mm) between the home position detector [2], and frame [3].
(5)
Tighten the four screws [4].
Fig. 3-8. Gap Adjustment
Fig. 3-9 Position of Four Screws