Table 2. F111 Air Volume Specifications for 3 Speed Models (Series 3).
Model
F111A1253W-3S 120 Vac, 60 Hz, 8.5A
F111A1063W-3S 120 Vac, 60 Hz, 7.2A
F111C1073W-3S 120 Vac, 60 Hz, 7.5A
F111C1003W-3S 120 Vac, 60 Hz, 7.0A
F111C1012W-3S 120 Vac, 60 Hz, 8.0A
F111A2253W-3S 230 Vac, 50 Hz, 4.2A
F111A2007W-3S 230 Vac, 50 Hz, 3.5A
F111C2073W-3S 230 Vac, 50 Hz, 4.0A
F111C2003W-3S 230 Vac, 50 Hz, 3.2A
F111C1053W-3S 230 Vac, 50 Hz, 3.5A
a
Same for Single Speed Models (Series 1 & 2).
.
TOP VIEW
48 (1219)
46-3/4 (1187)
POWER CONNECTION
POINT
Fig. 1. Approximate dimensions of F111
(Series 1,2,3) in in. (mm).
Installation Weight:
Approximately 115 lb to 155 lb (kg) depending on the filter
configuration. Refer to Table 3.
Table 3. Sorbent Module Weight.
Media
CPZ™ modules (2)
Sound Level at 3.3 ft (1m):
Low speed: 53 dBA (3 speed models only).
Medium speed: 57 dBA (3 speed models only)
High speed: 61 dBA.
Grille Type: Perforated metal.
Mounting: Recesses into opening on the ceiling.
Approvals:
Underwriters Laboratories Inc.: Listed.
Canadian Standards Association: Listed.
Particulates at
0.3 Micron
Voltage
(DOP Test)
95% ASHRAE
99.97% HEPA
95% ASHRAE
99.97% HEPA
95% at 0.3 micron CPZ™ modules 1125 (1910) 825 (1400)
95% ASHRAE
99.97% HEPA
95% ASHRAE
99.97% HEPA
95% at 0.3 micron CPZ™ modules
3/8 X 16
INTERNAL
THREAD (4)
24 (610)
22-1/2 (572)
17-1/4
(438)
CEILING
4-1/2
LINE
(114)
M11996A
Weight in lb (kg)
43 (20)
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER
Gas, V.O.C. and
Odor Control
Modules (2)
N/A
N/A
CPZ™ modules 1150 (1950) 825 (1400)
CPZ™ modules
N/A
N/A
CPZ™ modules 1025 (1740) 675 (1150)
CPZ™ modules
Accessories:
Black Color Grill
Remote 3-Speed Wall Switch
Replacement Parts See Parts List, Table 5.

PLANNING THE INSTALLATION

The number of F111 (series 1,2,3) air cleaners that are needed
is determined by taking into account the number of occupants
and the volume of the space. Type of contamination, outdoor
air quality and use of the area are also factors. Refer to Table
3 for general guidelines when determining how many air
cleaners are needed.
EXAMPLE: One air cleaner can provide 2.5 air changes per
hour in a 24,000 cubic feet (720 cubic meters) no
smoking area. Table 3 suggests two air cleaners
for a 24,000 cubic feet area because most areas
have contaminants that require more units to
provide quality air.
If any questions should arise concerning determining the
number of air cleaners needed for an area, consult your
distributor or local Honeywell Commercial Air Cleaner
Distributor.
Table 4. Determining the Minimum Number of
Air Cleaners Needed for a Space.
Space Volume
(L x W x H) in Cubic
Feet (Cubic Meter)
12000 to 18000
(360 to 540)
18001 to 35000
(540 to 1050)
3
a
High
Medium
in cfm
in cfm
3
3
(m
/hr)
(m
/hr)
1250 (2120) 800 (1360)
950 (1610) 775 (1310)
825 (1400) 700 (1190)
1125 (1910) 700 (1190)
900 (1530) 600 (1020)
825 (1400) 550 (930)
950 (1610) 625 (1060)
Number of
Number of Air
Persons Present
30 to 60
61 to 90
Low
in cfm
3
(m
/hr)
450 (760)
450 (760)
450 (760)
450 (760)
450 (760)
475 (810)
400 (680)
450 (760)
375 (640)
425 (720)
Minimum
Cleaners
1