Appendix Ⅰ Ⅰ (Reference for circuit diagnostics)
Ref. 4) Check sensors
Ref. 5) Check Door S/W
(Lamp on the REF)
1. If the Lamp turns on correctly when the door is open, it is normal. Press the door s/w and check it the lamp
turns off. If it doesn't work properly, check the door s/w on the refrigerator.
(Door open on the REF and the sensor part of the Main PCB)
1. Check the voltage between no. 5 "+" terminal and no.6 "-" terminal of CN30.
2. If 5V is checked when the door is open, it is normal.
3. If 0V is checked when the door is closed, it is normal. If it is not, check the door s/w and electric wire
connection.
(Lamp on the FRE)
1. If the Lamp turns on correctly when the door is open, it is normal. Press the door s/w and check it the lamp
turns off. If it doesn't work properly, check the door s/w on the FRE.
(Door open on the FRE and the sensor part of the Main PCB)
1. Check the voltage between no. 1 "+" terminal and no.2 "-" terminal of CN30.
2. If 5V is checked when the door is open, it is normal.
3. If 0V is checked when the door is closed, it is normal. If it is not, check the door s/w and electric wire
connection.
F-defroster SENSOR
R-defroster SENSOR
MEASURING TERMINALS
MEASURING TERMINALS
Disconnect the connector from the Main PCB,
than measure the resistance of the following
sensors.
1. Check the resistance the Freezer sensor cn30 between the no. 2 and 3.
2. Check the resistance the Fridge Room sensor cn30 between the no. 6 and 7.
3. Check the resistance the F Defrosting sensor cn30 between the no. 2 and 4.
4. Check the resistance the R Defrosting sensor cn30 between the no. 6 and 8.
5. Check the resistance between the no. and the ambient Air sensor cn31.
6. Check the resistance between the no. and of the Ice-Maker sensor cn90.
7. Check the resistance between the no. and of the CoolSelect Zone
sensor cn51.
8. Decide the sensor by comparing above resistances to the temperature of
each sensor with the conversion table of sensor resistance and voltage from
the reference temperature of Ref. 6 on this manual.
※When the resistance is ∞Ωor 0Ω,check the connection of electric wire and
sensorconnector.
Check the condition in power on. Door S/W
have 2 contact points. One contact point
perceives the door open/close by DC 5V on
the PCB. Another contact point turns on/off
the Lamp.