AC operation
1. Start
the engine and make sure the pilot lamp comes on. If not, the fila-
ment may be burnt out.
2. Plug in the appliance.
CAUTION:
Be sure that appliances
do not exceed the rated load for more
than 30 minutes,
and never exceed the maximum
load. Substantial
over-.
loading
will
switch
off the circuit
breaker.
Lesser overloading
will
not
switch
off the circuit
breaker and will shorten
the service life of the gen-
erator.
3. Check the frequency
meter to verify that the generator is operating at
60 Hz. If it is not, turn the governor adjustment screw to increase or
decrease engine speed until the correct frequency is obtained (meter bar
next to 60 will vibrate).
NOTE:
l
An overloaded AC circuit will trip the AC circuit breaker. If this occurs,
wait a few minutes before pushing the circuit breaker to resume operation.