Honda EB11000 Owner's Manual page 58

Honda generator owner's manual
Hide thumbs Also See for EB11000:
Table of Contents

Advertisement

Charging
The generator's engine has an approximate 3-amp charging system
to charge the battery while the engine is running. If the generator is
only used periodically, the battery must be charged monthly
to
maintain the battery service life.
A lead acid battery self discharges a t a rate of 0.5- 1 .O% per day. This
means that the battery, if the generator is not operated in a month,
can discharge as much as 30% in the same period. This could cause
the engine not to crank or shorten the service life of the battery. To
charge the battery, follow the procedures below.
The battery is rated at 24AH (ampere-hours)/5 HR. 10% of the ampere-
hour rating should be used as the charging current. A battery charger
should be used that can be adjusted
to deliver 2.4 amps.
The battery gives off explosive gasses; keep sparks, flames and
cigarettes away from the battery while charging. Provide adequate
ventilation when charging.
1.Remove the front cover and the battery
(see pages 52-53 ).
2. Remove the battery cell caps.
3.Connect the battery changer
following the manufacturer's
instructions.
4.Charge the battery 3-4 hours.
5.After the battery is charged, inspect the electrolyte level in each of
the cells. Add distilled water as necessary (see page 55
).
6. Install the battery cell
caps.
7.Clean the outside of the battery and the battery tray
with a solution
8. Install the battery and the front cover
(see page 52
&
54
).
of baking soda and water.
56

Hide quick links:

Advertisement

Table of Contents
loading