CentralPneumatic 68019 Owner's Manual

CentralPneumatic 68019 Owner's Manual

18 gauge 2-in-1 air nailer/stapler

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for CentralPneumatic 68019

  • Page 2: Table Of Contents

    National pipe thread, straight NIOSH-approved dust mask/respirator. WARNING marking concerning WARNING marking concerning Risk of Eye Injury. Wear ANSI-approved Risk of Explosion. safety goggles with side shields. Table A: Symbol Definitions Page 2 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 3: Work Area

    A dust mask, non-skid safety shoes the tool is able to fire a fastener. and a hard hat must be used for the applicable conditions. Wear heavy- duty work gloves during use. Item 68019 For technical questions, please call 1-800-444-3353. Page 3...
  • Page 4: Tool Use And Care

    Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air-pressure range. SAVE THESE INSTRUcTIONS. Page 4 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 5 17. Keep clear of the workpiece near the area being fastened. Fasteners may bend sideways during firing, causing them to exit the workpiece at an unexpected point, causing personal injury. Item 68019 For technical questions, please call 1-800-444-3353. Page 5...
  • Page 6 If you feel any symptoms related to vibration (such in this manual. If abnormal vibration occurs, as tingling, numbness, and white or blue fingers), stop immediately. seek medical advice as soon as possible. SAVE THESE INSTRUcTIONS. Page 6 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 7: Specifications

    1/4″ - 18 NPT Air Consumption 0.5 CFM @ 90 PSI Safety Mechanism Type Full Sequential Nail Type 18 Gauge 5/8″ - 2″ Brad Staple Type 18 Gauge 5/8″ - 1-1/2″ Narrow Crown Item 68019 For technical questions, please call 1-800-444-3353. Page 7...
  • Page 8 Air Inlet plug Trigger Latch Safety Nosepiece Safety Nosepiece - Also called the workpiece contact, the Safety Nosepiece helps prevent the tool from firing unless it is pressed against an object. Page 8 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 9: Setup

    3. The air hose must be long enough to reach the work area with enough extra length to allow free movement while working. Item 68019 For technical questions, please call 1-800-444-3353. Page 9...
  • Page 10 Page 10 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 11 Item 68019 For technical questions, please call 1-800-444-3353. Page 11...
  • Page 12: Operation

    The tool must not cycle (fire). it repaired by a qualified service technician. If it fails to perform in the manner explained in bold, have it repaired by a qualified service technician. Page 12 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 13: Safety Goggles With Side Shields

    Squeeze the trigger to fire a fastener. d. Release the trigger again. e. clean external surfaces with clean, dry cloth. f. Store indoors out of children’s reach. Item 68019 For technical questions, please call 1-800-444-3353. Page 13...
  • Page 14: Maintenance

    • misalignment or binding of moving parts, safely and will also reduce wear on the tool. • cracked or broken parts, and • any other condition that may affect its safe operation. Page 14 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 15: Clearing Jams

    6. Inspect the Drive Guide for any bends or serviced by a qualified technician. breakage. If it is damaged, do not use the tool until it is repaired by a qualified technician. Item 68019 For technical questions, please call 1-800-444-3353. Page 15...
  • Page 16: Troubleshooting

    3. Replace damaged components. 4. Dirty, worn or damaged valve. 4. Clean or replace valve assembly. Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect air supply before service. Page 16 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 17 Note: If product has no serial number, record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Item 68019 For technical questions, please call 1-800-444-3353. Page 17...
  • Page 18: Parts List And Diagram

    Latch Rectangle Gasket Latch Spring Valve Seat Grip O-Ring O-Ring Valve Stem Air Inlet Cap O-Ring Air Inlet Plug Valve Sleeve Plug Cap Valve Spring Trigger Socket Head Screw (M4x.70x10mm) Page 18 For technical questions, please call 1-800-444-3353. Item 68019...
  • Page 19 Item 68019 For technical questions, please call 1-800-444-3353. Page 19...
  • Page 20: Warranty

    Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.

This manual is also suitable for:

Centralpneumatic