TAKING CARE OF UNEXPECTED PROBLEMS
BATTERY
WILL
NOT
CHARGE AND ELECTRIC
STARTER WILL NOT
OPERATE
The battery-charging (ACG) circuit
and the electric starter relay circuit
are protected by the 10, 15 and 30-
ampere main fuses and 150-ampere
ACG fuse. If the fuse burns out, the
engine will not charge the battery,
and the electric starter will not
operate.
The ignition switch is protected by
the 10-ampere main fuse. If the fuse
bums out, the engine will not start or
run, and the power tridtilt switch
will not oprate.
Fuse Replacement
Main Fuse
1 . With the engine stopped, remove
the engine cover.
2. Remove the fuse covers.
3. Remove and inspect the fuses. If a
fuse is burnt out, install a
replacement fuse of the specified
rating. The outboard motor is
supplied with spare fuses in the
fuse holders.
MAIN FUSES: 10
A, 15 A,
30 A
W
I
Never use a fuse with a rating
greater than specified. Serious
damage to the electrical system
could result.
FUSES (10A. 15A. 30A)
I
SPARE FUSES
FUSE CASE
(lOA, 15A, 30A)
4. Reinstall the fuse covers and the
engine cover.
Before further operation, try to
determine and correct the electrical
problem that caused the fuse to
burn out. An uncorrected electrical
problem may cause the fuse to
bum out again.
87