WELDING
CABLE SELECTION
When choosing welding cable, it is best to allow a comfortable safety margin.
The cable's length, gauge (diameter), and material all combine to determine
how much current it can safely carry. The table below gives the current carry-
ing capacity of various lengths and gauges of standard copper welding cable.
I
I
I
LENGTH IN FEET*
I
CABLE
CAB L,E
GAUGE
DIA.
O-50 FT.
50-100 FT.
loo-250 FT.
CURRENT CAPACITY AMPERES
1
.644
250
200
170
2
.604
200
195
150
* Lengths given are for the combined length of the positive and negative
cables.
CAUTION:
An undersize
cable will
offer
unacceptably
high resistance
to
current
flow
from
the welder.
This will lead to poor quality
welds and will
shorten the life of the generator/welder.
OPERATING
RATE
The welder should not be operated continuously
at high current settings. Th,e
proportion
of welding time to "rest" time is called the Operating Rate. For
example: The welder's Operating Rate at 1.10 Amps is 70%. This means that
in a given 10 minutes period actual welding can be performed for a total of
7 minutes. Use the table below to determine the Operating Rate for other
current settings.
Current
170A
Rate
20%
150A
30%
130A
50%
IlOA
Below 90A
70%
100%