AC APPLICATIONS
Before connecting
an appliance or power cord to the generator:
l
Make sure that it is in good working
order.
Faulty appliances
or
power cords can create a potential for electrical
shock.
l
If an appliance begins to operate abnormally,
becomes sluggish or
stops suddenly,
turn it off immediately.
Disconnect
the appliance,
and determine whether the problem is the appliance,
or if the rated
load capacity of the generator
has been exceeded.
. Make sure that the electrical rating of the tool or appliance does not
exceed that of the generator.
Never exceed the maximum
power
rating of the generator,
Power levels between
rated and maximum
may be used for no more than 30 minutes.
NOTlCE]
Substantial
overloading
will open the circuit
breaker.
Exceeding
the time limit for maximum
power operation
or slightly
overload-
ing the generator
may not switch
the circuit
breaker
OFF, but will
shorten
the service
life of the generator.
Limit operation
requiring
maximum power to 30 minutes.
Maximum
power is:
10.5 kVA
For continuous
operation,
do not exceed the rated power.
Rated power is:
9.5 kVA
In either case, the total power requirements
(VA) of all appliances
connected
must be considered.