MVC-CD250/CD400

10. Auto White Balance 3200K Standard Data Input 2

RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance 3200K Standard Data Input 2" is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
6
B6
4
6
B6
5
6
37
6
6
01
7
6
02
Note 2: The adjustment data will be automatically input to page:
F, address: 7C to 7F.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
37
3
6
B6
4
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
F
7C to 7F
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Perform "Picture Frame set-
ting ". (Refer to page 5-15)
Note down the data.
03
04
0B
Press PAUSE button. (Note 3)
Check the data changes to
"01".
Procedure
00
Press PAUSE button.
00
"Set data noted down at step
00
3, and press PAUSE button."
Release the data setting per-
formed at step 1. (Refer to
page 5-14)

11. Auto White Balance 3200K Standard Data Input 3

RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance 3200K Standard Data Input 3" is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
6
B6
4
6
B6
5
6
37
6
6
01
7
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 84 to 87.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
37
3
6
B6
4
5-22
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
F
84 to 87
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Perform "Picture Frame set-
ting ". (Refer to page 5-15)
Note down the data.
03
06
0B
Press PAUSE button. (Note 3)
Check the data changes to
"01".
Procedure
00
Press PAUSE button.
00
"Set data noted down at step
00
3, and press PAUSE button."
Release the data setting per-
formed at step 1. (Refer to
page 5-14)