External Trigger Parameters

Absolute Maximum
Maximum Input Voltage
Maximum Input Current
Parameter Values
Input Resistance to
Ground
Maximum Input Low
Voltage Logical Low Level
Input High Voltage
Threshold
6 - 2
Low Value: -0.5 Volts
High Value: +5.5 Volts
Low Value: -6 Milliamperes
Low Value: 9.7 KΩ
Nominal Value: 10.0 KΩ
High Value: 10.3 KΩ
High Value: 0.8 Volts
Low Value: 2.6 Volts
The input is protected by an
input protection diode on the
ground side.
The input voltage can be
below ground provided it is
current limited below the value
shown on the next line of this
table.
Input protection diode current.
The limiting factor on current
is the dissipation in the 1KΩ,
0402 resistor (not the gate
diode limit).
Pull down resistor loading.
Value does not include
harness drops or margin for
noise.
Value does not include
harness drops or margin for
noise.