Settings with switches and jumpers

Your mainboard is equipped with switches or jumpers. The positions of the switches or jumpers are
shown on page "Cover".
ON
1
SKP
i
The clock frequency of the processor is set automatically.
Skipping system and BIOS Setup password - switch 1 / pin pair 1
Switch 1 / pin pair 1 enables skipping the system and BIOS Setup password.
On
System and BIOS Setup password are skipped when the device is switched on and
may be changed.
Off
System and BIOS Setup password must be entered when the device is switched on.
Recovering System BIOS - switch 2 / pin pair 2
Switch 2 / pin pair 2 enables recovery of the old system BIOS after an attempt to update has failed.
To restore the old BIOS you need a Flash BIOS Diskette (see "BIOS update" chapter).
On
The System BIOS executes from floppy drive A: and the inserted "Flash-BIOS-
Diskette" restores the System BIOS on the mainboard.
Normal operation (default setting).
Off
Reserved - switch 3 and switch 4 (if present)
Switch 3 and 4 are reserved.
A26361-D1567-Z121-1-6319
1 2 3 4
2
RCV
Switch 1 = Skipping system and BIOS Setup
password
Switch 2 = System BIOS recovery
Switch 3 = must always be set to off
Switch 4 = must always be set to off
Pin pair 1 inserted =
Skipping system and BIOS Setup password
Pin pair 2 inserted = System BIOS recovery
Any other setting =
State of supply; jumper has no function
English - 17