Dell PowerEdge M620 Owner's Manual page 109

Hide thumbs Also See for PowerEdge M620:
Table of Contents

Advertisement

Error Code
Message Information
Details
Action
PST0138
Message
LCD Message
Details
Action
PST0139
Message
LCD Message
Details
Action
PST0140
Message
LCD Message
Details
Action
PST0141
Message
LCD Message
Details
Action
PST0142
Message
LCD Message
Details
Action
System BIOS detected a parity error during post.
Remove and reapply input power. If the issue persists, see
Help.
SuperIO failed.
SuperIO failure. Power cycle system.
System BIOS detected a failure with the SIO.
Remove and reapply input power. If the issue persists, see
Help.
Keyboard controller failed.
Keyboard controller failed. Power cycle system.
System BIOS detected a failure with the Keyboard Controller.
Remove and reapply input power. If the issue persists, see
Help.
System management interrupt initialization failed.
SMI initialization failed. Power cycle system.
System BIOS failed to initialize the system management interrupt.
Remove and reapply input power. If the issue persists, see
Help.
QuickPath Interconnect (QPI) fatal error.
QuickPath Interconnect (QPI) fatal error.
Quick Path Interconnect failed during system POST.
Reboot the system. If problem persists, remove input power and re-
seat processors.
MRC fatal error.
Memory initialization error.
BIOS Memory testing failed.
Compare system memory installation to supported system memory
configurations. Reduce system configuration to minimum memory
configuration.
Getting
Getting
Getting
Getting
109

Advertisement

Table of Contents
loading

Table of Contents