REC/PB

REC/PB FUNCTION
Item
Selects the recording method.
RECORDING
NORMAL: Normal recording
LOOP: Loop recording
Selects whether recording and stopping is performed automatically in accordance with the
record and stop signals in the HD SDI
TYPE1:
Recording and stopping is performed automatically in accordance with the record and stop
signals in the LTC information attached to HD SDI signals.
TYPE2:
Recording and stopping is performed automatically in accordance with the record and stop
signals in the SVITC information attached to HD SDI signals.
OFF:
Recording and stopping is not performed automatically.
AUTO REC
Note:
• SD SDI signals are not supported.
• When this is set to other than OFF and the status becomes REC PAUSE in REMOTE
mode, "AREC" is displayed in a superimposed screen.
• Set the REMOTE mode.
• To start automatic recording, press the [REC]
ously to switch the unit to the REC PAUSE state. This function does not work in any state
other than REC PAUSE. Also, the unit switches to the REC PAUSE state after an auto-
matic stop.
• In normal recording mode, this setting is not available and an automatic stop is not per-
formed.
Sets whether to perform repeat playback during playback.
ON:
Performs repeat playback. After the last clip is played, playback continues from the begin-
ning clip.
OFF: Does not perform repeat playback. Stops playback at the end of the last clip.
REPEAT PLAY
Note:
• Repeat playback is not available during TEXT MEMO playback.
• If a P2 card is removed during repeat playback, playback is stopped when a clip that
no longer exists is reached.
• Even if you insert a P2 card during repeat playback, the additional clips will not be
played back until you stop repeat playback and then start repeat playback again.
*
1
3G-SDI LEVEL-A, 3G-SDI LEVEL-B DL, and 1.5G-SDI signals are written as "HD SDI" signals.
86
Setup Menu: Menu List
Settings and brief function description
*
1
input signals from a camera-recorder.
and [PAUSE]
_ is the factory default setting.
FREQ indications
59.94Hz
59.94Hz
buttons simultane-
59.94Hz
50Hz
50Hz
50Hz